A certified tester connects a calibrated gauge to the test cocks, isolates each check valve, and measures how well it holds. On an RP, the relief valve opening point is measured too. Those readings decide pass or fail and go on the district's report.
Pricing
| Backflow size | Flat fee per backflow |
|---|---|
| Under 4" | $105 |
| 4" and larger | $175 |
Includes the test and filing with your water district. No hidden fees.
- Price$105 flat
- TimeUnder an hour
- SchedulingSame week
- FilingIncluded
Questions before you book? Call us. We're happy to explain.
What we check
- RP relief valve opens on time
- No visible leaks or damage
- Check valves hold above the minimum
- Both shutoffs seal
- Vacuum breaker air inlet works
Calibrated equipment, accurate readings
Every backflow test depends on a differential pressure gauge. It measures the small pressure differences across each check valve and, on an RP, the point where the relief valve opens. Those numbers decide whether your device passes.
A gauge that reads even slightly off can pass a bad device or fail a good one. That's why water districts require test gauges to be checked for accuracy on a regular schedule, and why our gauges are kept in calibration.
It's also why a test has to be done by a certified tester. Certification means the tester has been trained on the procedures and passed an exam on them. Your district won't accept a report without a certified tester's signature and the gauge details listed.
What the tester is actually doing
First, the tester makes sure the assembly is the right type for the connection and that nothing obvious is broken. Then the test cocks are flushed to clear out debris that could throw off the readings.
Next, the downstream shutoff valve is closed. With the gauge hooked to the test cocks, the tester measures how well the first check holds, then the second. On an RP, the relief valve opening point is measured too. On a vacuum breaker, the air inlet and check are tested instead.
Finally, the tester opens the valves, checks for leaks, and puts the test cock caps back on. The whole process for a typical assembly takes 20 to 45 minutes. Larger devices and ones in tight spaces can take a bit longer.
Why assemblies fail
Debris is behind most failed tests. Grit and scale from the main lodge on a check seat and keep it from sealing. Often, cleaning it out is all it takes.
Aging rubber comes next. Discs, seats and o-rings stiffen and crack over time. A rebuild kit replaces them and usually costs far less than a new device.
Sometimes it's a tired spring, a torn relief valve diaphragm, or a body that cracked in a freeze or got hit by a mower or car. Springs and diaphragms can be replaced. A cracked body generally can't. In every case, you'll see the failed reading and hear the likely cause before we do anything.
The report your district receives
Your water district judges compliance by the report, not the visit. The report shows the address, the device make, model, size and serial number, its location, and every reading taken.
It also carries the tester's certification and gauge details, plus the result: pass, fail, or pass after repair, with any replaced parts listed.
Districts don't all use the same form, and many have deadlines for submitting reports after a test. We take care of that part and send you a copy. Keep it somewhere easy to find, since escrow companies, landlords and city inspectors sometimes ask for it.
The parts the test depends on
An assembly has small valves called test cocks where the gauge connects, plus a shutoff valve on each end. If a test cock is clogged or a shutoff won't close fully, the test can't be done accurately.
We check these before starting. Clogged test cocks can often be cleared on the spot. A shutoff valve that won't seal may need repair before the device can be tested properly, and we'll explain it if that's the case.
Testing after repairs, moves and installs
Annual tests aren't the only ones. After any repair, the assembly must be retested. When a device is relocated or reinstalled, it's tested again. New devices get a startup test.
The procedure is the same each time, and each produces a report for the district. If we did the work, that follow-up test is part of the job.
What if it fails?
You see the readings and get a price for the fix before we do anything. See assembly repair.
Questions
How long does an assembly test take?
Most take 20 to 45 minutes per device, depending on size and access.
Will I see the readings?
Yes. They're on your copy of the report, and the tester can walk you through them on site.
Do you need to shut my water off?
Only for a few minutes during the test. We'll let you know before we close the valves.
Can a device pass one year and fail the next?
Yes. Debris and wear build up over time, which is exactly why the test is yearly.
Is the gauge calibrated?
Yes. Districts require test gauges to be calibrated on a schedule, and ours are.
Who gets the test results?
Your water district gets the report, and you get a copy too.
Why Pasadena customers choose us
We focus on backflow prevention, so we know the devices, the test procedures and what your water district expects to see. Our testers are certified, our gauges are kept in calibration, and we'll explain what we find in plain terms.
You'll always know the price before work begins. Testing is $105 per device under 4 inches and $175 for 4 inches and larger, and other work is quoted free. Our office answers seven days a week, 6am to midnight, and emergency calls are answered 24/7.
Many of the people who call us have never dealt with a backflow device before, and that's fine. We'll tell you where the device is, what the test involves, and what the readings mean, without the jargon. If a repair or replacement comes up, you'll get the reasons and the price in writing so you can decide on your own schedule. Nothing gets done without your okay.
Serving Pasadena and nearby cities
We provide backflow assembly testing throughout Pasadena and nearby, including South Pasadena, San Marino, Altadena, East Pasadena and Highland Park. Most appointments are available within the week.