Placement matters as much as the device. RPs must stay above ground to drain, and vacuum breakers must sit above every outlet they protect. We leave room for yearly testing and add a cage where theft is a concern.
- PriceFree quote
- TimeUsually 1 day
- TestIncluded
- FilingIncluded
Questions before you book? Call us. We're happy to explain.
Installation rules we follow
- Easy access for annual testing
- Relief valves free to drain
- PVBs and SVBs set high enough
- Cages or covers where theft or freezing is a risk
Placement and height
Where an assembly sits affects whether it can work and whether it passes inspection. RP assemblies must be installed above ground, with enough space under them for the relief valve to drain freely. Putting an RP in a pit or a box that floods is one of the most common mistakes we see.
Pressure vacuum breakers and spill-resistant vacuum breakers have to be higher than the highest sprinkler head or outlet they protect, usually by at least 12 inches. On hillside lots, that can mean placing the device near the top of the yard instead of by the meter.
Double checks have more flexibility and are sometimes placed in vaults, especially on fire lines, but they still need room to be tested and repaired.
Leaving room to test and service
Every backflow assembly has to be tested every year, so it needs to be reachable. That means space around the test cocks for the gauge hoses, room to turn the shutoff valves and enough clearance to remove the check covers for repairs.
Devices wedged against walls, buried in shrubs or installed overhead in tight ceilings turn a 30-minute test into a two-hour job, or make repairs impossible without cutting pipe. We install with access in mind from the start.
We also think about who needs to reach it. A device behind a locked gate is fine for a home, but a commercial property might want it where a tester can get to it without an escort.
Freeze and theft protection
Freezes aren't common here, but inland and higher areas can get a cold snap that cracks a brass body or bonnet in one night. Insulated covers or enclosures help where that's a risk.
Theft is often the bigger threat. Brass devices near streets and lots attract scrap thieves, and a stolen device means an open line and a rush repair. A locking cage on a concrete pad is the standard fix.
We'll suggest protection based on the location, and a cage or cover can be included in your installation quote.
Startup test and the first report
Once an assembly is installed and the lines are flushed, we run the startup test. This is the same procedure used each year, and it confirms the device was installed correctly and works as designed.
The passing report is filed with your water district, which adds the device to its records and sets the first annual due date. You get a copy for your files.
From then on, the device needs an annual test. We can remind you before it's due, or you can add due date management and we'll handle the scheduling every year.
Fixing a poorly placed device
Sometimes an existing device just isn't in the right place. RPs below ground, PVBs lower than the sprinklers and devices with no room for testing are common examples.
Moving it means new piping and a retest afterward. If the device itself is still good, we can usually reuse it to save you money.
Working with contractors
Construction projects have a lot of moving parts. We coordinate with general contractors, plumbers and landscapers to install the assembly at the right stage and test it once water is on.
Since final inspection often needs the startup report, we file it promptly.
Pipe, fittings and supports
What connects to the assembly matters as much as the assembly. We use potable-rated fittings sized to the device and add unions where they'll make later repairs simpler. Bigger assemblies get supports so the pipe isn't carrying the load.
Outdoors, we choose fittings that stand up to sun, soil and water. You won't see these choices on the report, but they decide whether the install lasts or starts leaking in a few years.
After installation
The first test and report are included. From then on, plan on an annual test.
Questions
Do you add a cage or cover?
If theft or freezing is a risk, we recommend one and include it in the quote.
Can an RP go underground?
No. The relief valve has to drain, so RPs go above ground.
Can a PVB go next to the meter?
Only if the meter is higher than every sprinkler it protects. On sloped yards it often needs to go uphill.
How long does installation take?
Most installs for 2-inch and smaller assemblies take a day.
Can you move an existing assembly?
Yes. A moved assembly has to be retested afterward, and we include that.
Do you pour a pad for a cage?
Yes, when a cage is part of the job we include the pad it bolts to.
Why Pasadena customers choose us
We focus on backflow prevention, so we know the devices, the test procedures and what your water district expects to see. Our testers are certified, our gauges are kept in calibration, and we'll explain what we find in plain terms.
You'll always know the price before work begins. Testing is $105 per device under 4 inches and $175 for 4 inches and larger, and other work is quoted free. Our office answers seven days a week, 6am to midnight, and emergency calls are answered 24/7.
Many of the people who call us have never dealt with a backflow device before, and that's fine. We'll tell you where the device is, what the test involves, and what the readings mean, without the jargon. If a repair or replacement comes up, you'll get the reasons and the price in writing so you can decide on your own schedule. Nothing gets done without your okay.
Serving Pasadena and nearby cities
We provide backflow assembly installation throughout Pasadena and nearby, including South Pasadena, San Marino, Altadena, East Pasadena and Highland Park. Most appointments are available within the week.